MultiScreenHTS Filter Plates with Hydrophilic Durapore® PVDF membrane
Supplier: Merck
MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics.
Expand 14 Items
Cation exchange chromatography columns, HiTrap™ SP FF
Supplier: Cytiva
HiTrap™ SP FF is pre-packed with SP Sepharose™ Fast Flow, and is a strong cation exchanger for small scale protein purifications as well as screening of binding and elutions conditions.
Expand 2 Items
Anti-Replication Protein A (Ab-2) (RPA34-19) Mouse Monoclonal Antibody
Supplier: Merck Millipore (Oncogene)
Anti-Replication Protein A (Ab-2) (RPA34-19) Mouse Monoclonal Antibody
Expand 1 Items
1,2-Dichlorobenzene anhydrous, 99 % 1 * 100 mL
Supplier: Merck
1,2-Dichlorobenzene anhydrous, 99 % 1 * 100 mL
Expand 1 Items
4,7,13,16,21,24-Hexaoxa-1,10-diazabicyclo[8.8.8]hexacosane (Kryptofix® 222) ≥99% (by GC) for synthesis, Sigma-Aldrich®
Supplier: Merck
4,7,13,16,21,24-Hexaoxa-1,10-diazabicyclo[8.8.8]hexacosane (Kryptofix® 222) ≥99% (by GC) for synthesis, Sigma-Aldrich®
Expand 6 Items
Vortex mixers, RX3 and ZX3
Supplier: VELP SCIENTIFIC
Vortex mixers with epoxy painted aluminium die-cast housing that provides good chemical resistance. Four feet give stability on the bench. Choice of two models.
Expand 1 Items
tert-Butyl methyl ether 99, GPR RECTAPUR®
Supplier: VWR Chemicals
tert-Butyl methyl ether 99, GPR RECTAPUR®
Expand 3 Items
VWR®, Chemical Resistant Coats, Polyester/Hydro-Tec, Reusable
Supplier: VWR Collection
These anti-static coats are manufactured from 99% polyester fibres with 1% Hydro-Tec finish (carbon treated), which makes them both extremely durable and excellent for repelling dirt, oil, chemicals and water. All coats feature a stand-up collar, two side pockets and one breast pocket, all three protected by a flap.
Expand 64 Items
Zinc protoporphyrin ≥95% (by TLC), Calbiochem®
Supplier: Merck Millipore (Calbiochem)
A potent and selective inhibitor of heme oxygenase, the enzyme which generates carbon monoxide (CO) and biliverdin.
Expand 1 Items
4-Aminophenylmercury acetate ≥90% (by HPLC), Calbiochem®, Sigma-Aldrich®
Supplier: Merck Millipore (Calbiochem)
An organomercurial agent used for the activation of latent MMPs in vitro. Acts by facilitating the loss of the enzyme propeptide domain through an autolytic cleavage known as the cysteine switch.
Expand 1 Items
S-Nitrosoglutathione (GSNO) ≥95% (by HPLC), Calbiochem®, Sigma-Aldrich®
Supplier: Merck Millipore (Calbiochem)
A utility carrier of nitric oxide.
Expand 3 Items
J.T.Baker®, Robotic Tips Type HT
Supplier: Avantor
Suitable for use on third party robotic instruments Hamilton Microlab Star and Nimbus. Available in conductive version, with or without filter, and in CE-IVD marked version for clinical diagnostic applications.
Expand 22 Items
MG-132 95% by HPLC 1 * 10 mg
Supplier: Merck Millipore (Calbiochem)
MG-132 95% by HPLC 1 * 10 mg
Expand 1 Items
SD-169 ≥97% (by HPLC), Calbiochem®, Sigma-Aldrich®
Supplier: Merck Millipore (Calbiochem)
The p38 MAP Kinase Inhibitor VII, SD-169, also referenced under CAS 1670-87-7, controls the biological activity of p38 MAP Kinase.
Expand 1 Items
Erastin ≥98% (by HPLC), solid, Calbiochem®, Sigma-Aldrich®
Supplier: Merck Millipore (Calbiochem)
Antitumor agent
Expand 1 Items
VWR®, Graduated Pipettes, Type 3, Class B
Supplier: VWR Collection
Borosilicate 9.1 glass.
Expand 8 Items
VWR® Separating Funnels, Squibb
Supplier: VWR Collection
Borosilicate 3.3 glass with NS-PE stopper.
Expand 12 Items
Test strips, total hardness, MQuant®, Supelco®
Supplier: Merck
MQuant® (MQ) test strips can be considered as a mobile laboratory on a few square millimeters of plastic strip. As a screening method they provide the user with a rapid overview of the situation, which helps in making the choice of what, and perhaps if, further analysis is required, thereby leading to potentially substantial savings in time and analytical resources. The strip is a biologically-degradable polyester foil and the low reagent content, in the reaction zones, assists problem-free waste disposal.
Expand 2 Items
epT.I.P.S.® Pipette Tips, BioBased Reloads
Supplier: EPPENDORF
Eppendorf epT.I.P.S.® BioBased Reloads in 'Biopur' grade innovate with cutting edge eco-friendly design. The tips are made from 90% plant-based material in a reloadable format. They ensure precision and purity, and are ideal for sensitive applications prioritising environmental responsibility.
Expand 6 Items
MMP-9/MMP-13 inhibitor I ≥95% (by HPLC), Millipore®
Supplier: Merck Millipore (Calbiochem)
A piperazine-based, cell-permeable, and highly potent inhibitor of MMP-9 (IC₅₀=900 pM) and MMP-13 (IC₅₀=900 pM).
Expand 1 Items
PIPPS (1,4-Piperazinedipropanesulphonic acid) ≥97% (by titration analysis on dried basis), Calbiochem®
Supplier: Merck Millipore (Calbiochem)
A non-metal complexing, zwitterionic buffer with mixed-mode dissociation constants of pKa1 = 3.73 and pKa2 = 7.96 (100 mM, 25°C).
PIPPS has no interference at wavelengths longer than 240 nm.