  • Catalog No:
  • 735-0394
  • 735-0393
  • Plate types:
  • 6-well to 1536-well plates
  • 6-well to 1536-well plates
  • Interfaces:
  • Onboard software and serial RS-232 or USB for PC control
  • Onboard software and serial RS-232 or USB for PC control
  • Dispensing volume range:
  • Small tube dispensing cassette: 0,5 - 50 µl, in 0,5 µl increments
    Standard tube dispensing cassette: 5 - 2500 µl, in 5 µl increments
  • Small tube dispensing cassette: 0,5 - 50 µl, in 0,5 µl increments
    Standard tube dispensing cassette: 5 - 2500 µl, in 5 µl increments
  • Dispensing speed:
  • 96-well plate: 10 µl in 5 s, 20 µl in 5 s, 100 µl in 10 s
    384-well plate: 1 µl in 6 s, 5 µl in 9 s, 10 µl in 13 s, 20 µl in 21 s
    1536-well plate: 1 µl in 15 s, 5 µl in 28 s
  • 96-well plate: 10 µl in 5 s, 20 µl in 5 s, 100 µl in 10 s
    384-well plate: 1 µl in 6 s, 5 µl in 9 s, 10 µl in 13 s, 20 µl in 21 s
    1536-well plate: 1 µl in 15 s, 5 µl in 28 s
  • Dispensing accuracy (typical):
  • Small tube dispensing cassette: 2 µl, ±10%; 10 µl, ±5%
    Standard tube dispensing cassette: 20 µl, ±2%; 100 µl, ±1%
  • Small tube dispensing cassette: 2 µl, ±10%; 10 µl, ±5%
    Standard tube dispensing cassette: 20 µl, ±2%; 100 µl, ±1%
  • Dispensing precision:
  • Small tube dispensing cassette: 2 μl: CV ≤5%; 10 μl: CV ≤3%
    Standard tube dispensing cassette: 20 µl: CV ≤1,5%; 100 μl: CV ≤1%
  • Small tube dispensing cassette: 2 μl: CV ≤5%; 10 μl: CV ≤3%
    Standard tube dispensing cassette: 20 µl: CV ≤1,5%; 100 μl: CV ≤1%
  • Dead volume:
  • <1 ml for small tube dispensing cassette
    <7 ml for standard tube dispensing cassette
    Note: Reagents can be backflushed into the original reservoir to avoid loss of expensive reagents.
  • <1 ml for small tube dispensing cassette
    <7 ml for standard tube dispensing cassette
    Note: Reagents can be backflushed into the original reservoir to avoid loss of expensive reagents.
  • W×D×H:
  • 356×328×218 mm
  • 356×328×218 mm
  • Weight:
  • 9,1 kg
  • 9,1 kg

 

 

  •  
     
    Pk
     
     
  • Multidrop™ Combi+
    Multidrop™ Combi+
    735-0393
    5840330
    1
       
       
    1 * 1 items
    1 * 1 items - £28,430.00
    £28,430.00
    1 * 1 items
       £28,430.00

     
     
    Accessories
    Specifications
    Environmentally Preferable
    Plate types
    6-well to 1536-well plates
    Interfaces
    Onboard software and serial RS-232 or USB for PC control
    Dispensing volume range
    Small tube dispensing cassette: 0,5 - 50 µl, in 0,5 µl increments
    Standard tube dispensing cassette: 5 - 2500 µl, in 5 µl increments
    Dispensing speed
    96-well plate: 10 µl in 5 s, 20 µl in 5 s, 100 µl in 10 s
    384-well plate: 1 µl in 6 s, 5 µl in 9 s, 10 µl in 13 s, 20 µl in 21 s
    1536-well plate: 1 µl in 15 s, 5 µl in 28 s
    Dispensing accuracy (typical)
    Small tube dispensing cassette: 2 µl, ±10%; 10 µl, ±5%
    Standard tube dispensing cassette: 20 µl, ±2%; 100 µl, ±1%
    Dispensing precision
    Small tube dispensing cassette: 2 μl: CV ≤5%; 10 μl: CV ≤3%
    Standard tube dispensing cassette: 20 µl: CV ≤1,5%; 100 μl: CV ≤1%
    Dead volume
    <1 ml for small tube dispensing cassette
    <7 ml for standard tube dispensing cassette
    Note: Reagents can be backflushed into the original reservoir to avoid loss of expensive reagents.
    W×D×H
    356×328×218 mm
    Weight
    9,1 kg
  • Multidrop™ Combi+ SMART
    Multidrop™ Combi+ SMART
    735-0394
    5840340
    1
       
       
    1 * 1 items
    1 * 1 items - £31,890.00
    £31,890.00
    1 * 1 items
       £31,890.00

     
     
    Accessories
    Specifications
    Environmentally Preferable
    Plate types
    6-well to 1536-well plates
    Interfaces
    Onboard software and serial RS-232 or USB for PC control
    Dispensing volume range
    Small tube dispensing cassette: 0,5 - 50 µl, in 0,5 µl increments
    Standard tube dispensing cassette: 5 - 2500 µl, in 5 µl increments
    Dispensing speed
    96-well plate: 10 µl in 5 s, 20 µl in 5 s, 100 µl in 10 s
    384-well plate: 1 µl in 6 s, 5 µl in 9 s, 10 µl in 13 s, 20 µl in 21 s
    1536-well plate: 1 µl in 15 s, 5 µl in 28 s
    Dispensing accuracy (typical)
    Small tube dispensing cassette: 2 µl, ±10%; 10 µl, ±5%
    Standard tube dispensing cassette: 20 µl, ±2%; 100 µl, ±1%
    Dispensing precision
    Small tube dispensing cassette: 2 μl: CV ≤5%; 10 μl: CV ≤3%
    Standard tube dispensing cassette: 20 µl: CV ≤1,5%; 100 μl: CV ≤1%
    Dead volume
    <1 ml for small tube dispensing cassette
    <7 ml for standard tube dispensing cassette
    Note: Reagents can be backflushed into the original reservoir to avoid loss of expensive reagents.
    W×D×H
    356×328×218 mm
    Weight
    9,1 kg