Northern Ireland
Order Entry
Drying and heating chambers with forced convection, FP series Avantgarde.Line
Drying and heating chambers with forced convection, FP series Avantgarde.Line
 :  Binder
 
undefined
Drying and heating chambers with forced convection, FP series Avantgarde.Line
 :  Binder

Specifications

  • Catalog No:
  • 466-0654
  • 466-0653
  • 466-0656
  • 466-0655
  • Model:
  • FP 115
  • FP 56
  • FP 720
  • FP 260
  • Temperature fluctuation (time):
  • 0,3 °C @ 150 °C
  • 0,4 °C @ 150 °C
  • 0,6 °C @ 150 °C
  • 0,4 °C @ 150 °C
  • Temperature range:
  • Ambient +10…300 °C
  • Ambient +10…300 °C
  • Ambient +12…300 °C
  • Ambient +10…300 °C
  • Temperature variation (spatial):
  • 1,4 °C @ 150 °C
  • 1,4 °C @ 150 °C
  • 2,4 °C @ 150 °C
  • 1,7 °C @ 150 °C
  • Capacity:
  • 116 L
  • 60 L
  • 741 L
  • 259 L
  • Convection type:
  • Forced convection
  • Forced convection
  • Forced convection
  • Forced convection
  • Heat-up time:
  • 19 min to 150 °C
  • 15 min to 150 °C
  • 25 min to 150 °C
  • 19 min to 150 °C
  • Recovery Time:
  • 5 min after 30 second opening at 150 °C
  • 4 min after 30 second opening at 150 °C
  • 6 min after 30 second opening at 150 °C
  • 6 min after 30 second opening at 150 °C
  • Shelves supplied (max.):
  • 2(5)
  • 2(5)
  • 2(16)
  • 2(8)
  • Max. load per shelf:
  • 30 kg
  • 30 kg
  • 45 kg
  • 40 kg
  • Int. W×D×H:
  • 550×383×550 mm
  • 400×342×400 mm
  • 1000×574×1300 mm
  • 650×512×780 mm
  • Ext. W×D×H:
  • 714×690×732 mm
  • 564×648×622 mm
  • 1165×910×1590 mm
  • 814×840×962 mm
  • Electrical:
  • 230 V, 1 phase, 50/60 Hz
  • 230 V, 1 phase, 50/60 Hz
  • 400 V, 3 phase, 50/60 Hz
  • 230 V, 1 phase, 50/60 Hz
  • Nominal power consumption:
  • 1,4 kW
  • 1,2 kW
  • 4,5 kW
  • 2,5 kW
  • Weight:
  • 62 kg
  • 44 kg
  • 194 kg
  • 96 kg

Specifications

 

  •  
     
    Pk
     
     
  • FP 56 drying and heating chamber, 70 kg permitted load, 1 door
    FP 56 drying and heating chamber, 70 kg permitted load, 1 door
    466-0653
    9010-0363
    1
       
       
    1 * 1 items
    1 * 1 items - £3,910.00
    £3,910.00
    1 * 1 items
       £3,910.00

     
     
    Accessories
    Specifications
    Model
    FP 56
    Environmentally Preferable
    Temperature fluctuation (time)
    0,4 °C @ 150 °C
    Temperature range
    Ambient +10…300 °C
    Temperature variation (spatial)
    1,4 °C @ 150 °C
    Capacity
    60 L
    Convection type
    Forced convection
    Heat-up time
    15 min to 150 °C
    Recovery Time
    4 min after 30 second opening at 150 °C
    Shelves supplied (max.)
    2(5)
    Max. load per shelf
    30 kg
    Int. W×D×H
    400×342×400 mm
    Ext. W×D×H
    564×648×622 mm
    Electrical
    230 V, 1 phase, 50/60 Hz
    Nominal power consumption
    1,2 kW
    Weight
    44 kg
  • FP 115 drying and heating chamber, 150 kg permitted load, 1 door
    FP 115 drying and heating chamber, 150 kg permitted load, 1 door
    466-0654
    9010-0364
    1
       
       
    1 * 1 items
    1 * 1 items - £4,890.00
    £4,890.00
    1 * 1 items
       £4,890.00

     
     
    Accessories
    Specifications
    Model
    FP 115
    Environmentally Preferable
    Temperature fluctuation (time)
    0,3 °C @ 150 °C
    Temperature range
    Ambient +10…300 °C
    Temperature variation (spatial)
    1,4 °C @ 150 °C
    Capacity
    116 L
    Convection type
    Forced convection
    Heat-up time
    19 min to 150 °C
    Recovery Time
    5 min after 30 second opening at 150 °C
    Shelves supplied (max.)
    2(5)
    Max. load per shelf
    30 kg
    Int. W×D×H
    550×383×550 mm
    Ext. W×D×H
    714×690×732 mm
    Electrical
    230 V, 1 phase, 50/60 Hz
    Nominal power consumption
    1,4 kW
    Weight
    62 kg
  • FP 260 drying and heating chamber, 270 kg permitted load, 1 door
    FP 260 drying and heating chamber, 270 kg permitted load, 1 door
    466-0655
    9010-0365
    1
       
       
    1 * 1 items
    1 * 1 items - £6,750.00
    £6,750.00
    1 * 1 items
       £6,750.00

     
     
    Accessories
    Specifications
    Model
    FP 260
    Environmentally Preferable
    Temperature fluctuation (time)
    0,4 °C @ 150 °C
    Temperature range
    Ambient +10…300 °C
    Temperature variation (spatial)
    1,7 °C @ 150 °C
    Capacity
    259 L
    Convection type
    Forced convection
    Heat-up time
    19 min to 150 °C
    Recovery Time
    6 min after 30 second opening at 150 °C
    Shelves supplied (max.)
    2(8)
    Max. load per shelf
    40 kg
    Int. W×D×H
    650×512×780 mm
    Ext. W×D×H
    814×840×962 mm
    Electrical
    230 V, 1 phase, 50/60 Hz
    Nominal power consumption
    2,5 kW
    Weight
    96 kg
  • FP 720 drying and heating chamber, 315 kg permitted load, 2 doors
    FP 720 drying and heating chamber, 315 kg permitted load, 2 doors
    466-0656
    9010-0366
    1
       
       
    1 * 1 items
    1 * 1 items - £11,660.00
    £11,660.00
    1 * 1 items
       £11,660.00

     
     
    Accessories
    Specifications
    Model
    FP 720
    Environmentally Preferable
    Temperature fluctuation (time)
    0,6 °C @ 150 °C
    Temperature range
    Ambient +12…300 °C
    Temperature variation (spatial)
    2,4 °C @ 150 °C
    Capacity
    741 L
    Convection type
    Forced convection
    Heat-up time
    25 min to 150 °C
    Recovery Time
    6 min after 30 second opening at 150 °C
    Shelves supplied (max.)
    2(16)
    Max. load per shelf
    45 kg
    Int. W×D×H
    1000×574×1300 mm
    Ext. W×D×H
    1165×910×1590 mm
    Electrical
    400 V, 3 phase, 50/60 Hz
    Nominal power consumption
    4,5 kW
    Weight
    194 kg

Analogue Output

Product Information

  •  
    Seq
    Description
    For
    Pk
     
     
  • 12
    Analogue output 4 - 20 mA - for temperature values (output not adjustable)
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,290.00
    £1,290.00

Access Port

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 02
    Access port with silicone plug, 10 mm, top
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £463.00
    £463.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 01
    Access port with silicone plug, 10 mm, right
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £463.00
    £463.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 09
    Access port with silicone plug, 100 mm, left
    FP 115, 260
    1
       
       
    1 * 1 items
    1 * 1 items - £1,130.00
    £1,130.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 11
    Access port with silicone plug, 100 mm, top
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,130.00
    £1,130.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 10
    Access port with silicone plug, 100 mm, right
    FP 115, 260
    1
       
       
    1 * 1 items
    1 * 1 items - £1,130.00
    £1,130.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 03
    Access port with silicone plug, 30 mm, left
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £605.00
    £605.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 05
    Access port with silicone plug, 30 mm, top
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £605.00
    £605.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 04
    Access port with silicone plug, 30 mm, right
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £605.00
    £605.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 06
    Access port with silicone plug, 50 mm, left
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £706.00
    £706.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 08
    Access port with silicone plug, 50 mm, top
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £706.00
    £706.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 07
    Access port with silicone plug, 50 mm, right
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £706.00
    £706.00

Gas-Tight Option Model

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 23
    Gas-tight option model - includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option  
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £1,560.00
    £1,560.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 25
    Gas-tight option model - includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option  
    FP 260
    1
       
       
    1 * 1 items
    1 * 1 items - £1,470.00
    £1,470.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 24
    Gas-tight option model - includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option  
    FP 115
    1
       
       
    1 * 1 items
    1 * 1 items - £1,470.00
    £1,470.00

HEPA Air Filter

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 26
    HEPA air filter - on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >99,995% at 0,3 µm)
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £1,950.00
    £1,950.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 27
    HEPA air filter - on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >99,995% at 0,3 µm)
    FP 115
    1
       
       
    1 * 1 items
    1 * 1 items - £1,950.00
    £1,950.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 28
    HEPA air filter - on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >99,995% at 0,3 µm)
    FP 260
    1
       
       
    1 * 1 items
    1 * 1 items - £1,950.00
    £1,950.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 29
    HEPA air filter - on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, >99,995% at 0,3 µm)
    FP 720
    1
       
       
    1 * 1 items
    1 * 1 items - £1,950.00
    £1,950.00

Inert Gas Connection

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 30
    Inert gas connection - with gas inlet and outlet, Ø10 mm, includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £1,610.00
    £1,610.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 31
    Inert gas connection - with gas inlet and outlet, Ø10 mm, includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option
    FP 115
    1
       
       
    1 * 1 items
    1 * 1 items - £1,610.00
    £1,610.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 32
    Inert gas connection - with gas inlet and outlet, Ø10 mm, includes additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option
    FP 260
    1
       
       
    1 * 1 items
    1 * 1 items - £1,610.00
    £1,610.00

Interior Lighting

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 38
    Interior lighting - 400 V option model
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £709.00
    £709.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 37
    Interior lighting - 230/240 V option model, with 15 W light bulb
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £613.00
    £613.00

Reinforced Inner Chamber

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 35
    Inner chamber, reinforced - max. total load 300 kg
    FP 260
    1
       
       
    1 * 1 items
    1 * 1 items - £2,470.00
    £2,470.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 36
    Inner chamber, reinforced - max. total load 350 kg
    FP 720
    1
       
       
    1 * 1 items
    1 * 1 items - £2,470.00
    £2,470.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 34
    Inner chamber, reinforced - max. total load 170 kg
    FP 115
    1
       
       
    1 * 1 items
    1 * 1 items - £2,470.00
    £2,470.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 33
    Inner chamber, reinforced - max. total load 85 kg
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £2,470.00
    £2,470.00

Calibration Certificate

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 14
    Calibration certificate, temperature - for temperature, measurement in center of chamber at specified temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £501.00
    £501.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 17
    Calibration certificate, temperature - temperature measurement includes certificate, 15 - 18 measuring points at specified temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,510.00
    £1,510.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 15
    Calibration certificate, temperature - temperature measurement includes certificate and 27 measuring points at specified temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,980.00
    £1,980.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 16
    Calibration certificate, temperature - temperature measurement includes certificate, 9 measuring points at specified temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,190.00
    £1,190.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 13
    Calibration certificate, expanded - for temperature; for extending the measurement in center of chamber to include another test temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £132.00
    £132.00

Measurement

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 39
    Measurement of air exchange rate - in accordance with ASTM D5374, definition and protocol according to ambient temperature
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £1,440.00
    £1,440.00

Temperature Sensor

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 40
    PT100 temperature sensor - additional flexible PT100, interior, for displaying the temperature on the unit display
    Series FP Avantgarde.Line
    1
       
       
    1 * 1 items
    1 * 1 items - £864.00
    £864.00

Door Gasket

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 18
    Door gasket - made of FKM, silicone-free
     
    FP 56
    1
       
       
    1 * 1 items
    1 * 1 items - £743.00
    £743.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 19
    Door gasket - made of FKM, silicone-free
     
    FP 115
    1
       
       
    1 * 1 items
    1 * 1 items - £792.00
    £792.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 20
    Door gasket - made of FKM, silicone-free
     
    FP 260
    1
       
       
    1 * 1 items
    1 * 1 items - £958.00
    £958.00

 

  •  
    For
    Pk
     
     
  • FP 720
    1
       
       
    1 * 1 items
    1 * 1 items - £1,310.00
    £1,310.00

Door Lock

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 21
    Door lock - lockable door handle
    FP 56, 115, 260
    1
       
       
    1 * 1 items
    1 * 1 items - £738.00
    £738.00

 

  •  
    Seq
    Description
    For
    Pk
     
     
  • 22
    Door lock - lockable door handle
    FP 720
    1
       
       
    1 * 1 items
    1 * 1 items - £738.00
    £738.00