Order Entry
Masterflex® L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, Avantor®
Masterflex® L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, Avantor®
 
undefined
Masterflex® L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, Avantor®
 

 

  • Model:
  • 06442-15
  • 06442-24
  • 06442-36
  • 06442-35
  • Length per pack:
  • 15,2 m (50 ft.)
  • 15,2 m (50 ft.)
  • 15,2 m (50 ft.)
  • 15,2 m (50 ft.)
  • Max. pressure:
  • 2,7 bar (40 psi)
  • 2,7 bar (40 psi)
  • 1,4 bar (20 psi)
  • 2,4 bar (35 psi)
  • Min. temperature:
  • –60 °C (–71 °F)
  • –60 °C (–71 °F)
  • –60 °C (–71 °F)
  • –60 °C (–71 °F)
  • Max. temperature:
  • 74 °C (165 °F)
  • 74 °C (165 °F)
  • 74 °C (165 °F)
  • 74 °C (165 °F)
  • Min. temperature (dynamic):
  • 0 °C (32 °F)
  • 0 °C (32 °F)
  • 0 °C (32 °F)
  • 0 °C (32 °F)
  • Max. temperature (dynamic):
  • 40 °C (104 °F)
  • 40 °C (104 °F)
  • 40 °C (104 °F)
  • 40 °C (104 °F)
  • Max. vacuum:
  • 660 mm Hg (26" Hg)
  • 660 mm Hg (26" Hg)
  • 610 mm Hg (24" Hg)
  • 660 mm Hg (26" Hg)
  • Pump series:
  • L/S
  • L/S
  • L/S
  • L/S
  • Regulatory approvals:
  • FDA;Non-DEHP;RoHS;USP
  • FDA;Non-DEHP;RoHS;USP
  • FDA;Non-DEHP;RoHS;USP
  • FDA;Non-DEHP;RoHS;USP
  • Sterilisation:
  • Autoclave, Ethylene Oxide, Gamma Irradiation
  • Autoclave, Ethylene Oxide, Gamma Irradiation
  • Autoclave, Ethylene Oxide, Gamma Irradiation
  • Autoclave, Ethylene Oxide, Gamma Irradiation
  • Sterilisation method autoclave:
  • Yes
  • Yes
  • Yes
  • Yes
  • Sterilisation method EtO:
  • Yes
  • Yes
  • Yes
  • Yes
  • Sterilisation method gamma:
  • Yes
  • Yes
  • Yes
  • Yes
  • Suction lift H₂O:
  • 8,8 m (29 ft.)
  • 8,8 m (29 ft.)
  • 8,3 m (27 ft.)
  • 8,8 m (29 ft.)
  • Warranty:
  • Out of box
  • Out of box
  • Out of box
  • Out of box

 

 

 

  •  
    Seq
    Tubing int.Ø
    Tubing material
    L/S Masterflex tubing size
    Hose barb size
    Maximum Flow Rate
    Pk
     
     
  • L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 15; 50 ft
    L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 15; 50 ft
    01
    4,80 mm (0,189")
    Chem-Durance® Bio
    15
    0,1875"
    1100 ml/min
    50 Feet
       
       
    1 * 50 Feet
    1 * 50 Feet - £444.00
    £444.00
    1 * 50 Feet
       £444.00

     
    CE certificate
    Avantor exclusive
     
    Specifications
    Model
    06442-15
    Environmentally Preferable
    Length per pack
    15,2 m (50 ft.)
    Max. pressure
    2,7 bar (40 psi)
    Min. temperature
    –60 °C (–71 °F)
    Max. temperature
    74 °C (165 °F)
    Min. temperature (dynamic)
    0 °C (32 °F)
    Max. temperature (dynamic)
    40 °C (104 °F)
    Max. vacuum
    660 mm Hg (26" Hg)
    Pump series
    L/S
    Regulatory approvals
    FDA;Non-DEHP;RoHS;USP
    Sterilisation
    Autoclave, Ethylene Oxide, Gamma Irradiation
    Sterilisation method autoclave
    Yes
    Sterilisation method EtO
    Yes
    Sterilisation method gamma
    Yes
    Suction lift H₂O
    8,8 m (29 ft.)
    Warranty
    Out of box
    CE certificate
    Avantor exclusive
  • L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 24; 50 ft
    L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 24; 50 ft
    02
    6,40 mm (0,252")
    Chem-Durance® Bio
    24
    0,25"
    1800 ml/min
    50 Feet
       
       
    1 * 50 Feet
    1 * 50 Feet - £611.00
    £611.00
    1 * 50 Feet
       £611.00

     
    CE certificate
    Avantor exclusive
     
    Specifications
    Model
    06442-24
    Environmentally Preferable
    Length per pack
    15,2 m (50 ft.)
    Max. pressure
    2,7 bar (40 psi)
    Min. temperature
    –60 °C (–71 °F)
    Max. temperature
    74 °C (165 °F)
    Min. temperature (dynamic)
    0 °C (32 °F)
    Max. temperature (dynamic)
    40 °C (104 °F)
    Max. vacuum
    660 mm Hg (26" Hg)
    Pump series
    L/S
    Regulatory approvals
    FDA;Non-DEHP;RoHS;USP
    Sterilisation
    Autoclave, Ethylene Oxide, Gamma Irradiation
    Sterilisation method autoclave
    Yes
    Sterilisation method EtO
    Yes
    Sterilisation method gamma
    Yes
    Suction lift H₂O
    8,8 m (29 ft.)
    Warranty
    Out of box
    CE certificate
    Avantor exclusive
  • L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 35; 50 ft
    L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 35; 50 ft
    03
    7,90 mm (0,311")
    Chem-Durance® Bio
    35
    0,375"
    2600 ml/min
    50 Feet
       
       
    1 * 50 Feet
    1 * 50 Feet - £754.00
    £754.00
    1 * 50 Feet
       £754.00

     
    CE certificate
    Avantor exclusive
     
    Specifications
    Model
    06442-35
    Environmentally Preferable
    Length per pack
    15,2 m (50 ft.)
    Max. pressure
    2,4 bar (35 psi)
    Min. temperature
    –60 °C (–71 °F)
    Max. temperature
    74 °C (165 °F)
    Min. temperature (dynamic)
    0 °C (32 °F)
    Max. temperature (dynamic)
    40 °C (104 °F)
    Max. vacuum
    660 mm Hg (26" Hg)
    Pump series
    L/S
    Regulatory approvals
    FDA;Non-DEHP;RoHS;USP
    Sterilisation
    Autoclave, Ethylene Oxide, Gamma Irradiation
    Sterilisation method autoclave
    Yes
    Sterilisation method EtO
    Yes
    Sterilisation method gamma
    Yes
    Suction lift H₂O
    8,8 m (29 ft.)
    Warranty
    Out of box
    CE certificate
    Avantor exclusive
  • L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 36; 50 ft
    L/S® High Performance Precision Pump Tubing, Chem-Durance® Bio, L/S 36; 50 ft
    04
    9,70 mm (0,382")
    Chem-Durance® Bio
    36
    0,375"
    3400 ml/min
    50 Feet
       
       
    1 * 50 Feet
    1 * 50 Feet - £751.00
    £751.00
    1 * 50 Feet
       £751.00

     
    CE certificate
    Avantor exclusive
     
    Specifications
    Model
    06442-36
    Environmentally Preferable
    Length per pack
    15,2 m (50 ft.)
    Max. pressure
    1,4 bar (20 psi)
    Min. temperature
    –60 °C (–71 °F)
    Max. temperature
    74 °C (165 °F)
    Min. temperature (dynamic)
    0 °C (32 °F)
    Max. temperature (dynamic)
    40 °C (104 °F)
    Max. vacuum
    610 mm Hg (24" Hg)
    Pump series
    L/S
    Regulatory approvals
    FDA;Non-DEHP;RoHS;USP
    Sterilisation
    Autoclave, Ethylene Oxide, Gamma Irradiation
    Sterilisation method autoclave
    Yes
    Sterilisation method EtO
    Yes
    Sterilisation method gamma
    Yes
    Suction lift H₂O
    8,3 m (27 ft.)
    Warranty
    Out of box
    CE certificate
    Avantor exclusive