Masterflex® L/S® Standard Digital Pump Systems, Avantor®
About this item
Designed with maintenance-free high-accuracy motor and a graphical interface—makes setup and operation easier than ever!
- Digital interface with graphical LCD shows pump performance and operating modes—continuous run, timed dispense, copy dispense, or volume dispense
- Select your preferred language from the user-friendly menu for programming and operation
- Dispense by Volume in ml (0.001 to 9,999 mL), L, or gal; Copy—1 to 9,999 dispense cycles; or Time—time interval of on/off cycles (1 sec to 99 hr, 59 min, 59 sec per cycle)Antidrip function ensures dispensing accuracy
- Brushless, maintenance-free motor offers ±0.1% speed control accuracy with a 6000 to 1 turndown ratio
- Models with open-head sensor stop drive motor when pump head is opened
These precision drives offer analog remote control options and simple programming—ideal for automated process applications. Drives feature a programmable dispense interval that lets you set the delay between dispense cycles for convenient, automated dispensing. Programmed calibration ensures dispense and display accuracy—drive stores one calibration value per tubing size.
Program the drive via the simple membrane keypad; keypad lock/unlock feature protects settings. Motor is reversible so you can purge tubing before or after pumping and pump fluid in either direction.
- Environmentally Preferable:
- Catalog No:
- MFLX77921-85-EU
- MFLX77921-65-UK
- MFLX77919-35-EU
- MFLX77919-25-EU
- MFLX77921-85-UK
- MFLX77921-75-EU
- MFLX77921-65-EU
- MFLX77919-35-UK
- MFLX77919-25-UK
- Model:
- 77921-85
- 77921-65
- 77919-35
- 77919-25
- 77921-85
- 77921-75
- 77921-65
- 77919-35
- 77919-25
- No. of channels:
- 4
- 1
- 4
- 8
- 4
- 1
- 1
- 4
- 8
- No. of rollers:
- 6
- 3
- 8
- 4
- 6
- 4
- 3
- 8
- 4
- Control type:
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Variable-Speed Digital
- Min. flow rate per channel:
- 0,047 ml/min
- 0,08 ml/min
- 0,0024 ml/min
- 0,0034 ml/min
- 0,047 ml/min
- 0,28 ml/min
- 0,08 ml/min
- 0,0024 ml/min
- 0,0034 ml/min
- Max. flow rate per channel:
- 280 ml/min
- 480 ml/min
- 12 ml/min
- 18 ml/min
- 280 ml/min
- 1700 ml/min
- 480 ml/min
- 12 ml/min
- 18 ml/min
- Min. flow rate:
- 0,188 ml/min
- 0,08 ml/min
- 0,0096 ml/min
- 0,0272 ml/min
- 0,188 ml/min
- 0,28 ml/min
- 0,08 ml/min
- 0,0096 ml/min
- 0,0272 ml/min
- Drive IP rating:
- IP 33
- IP 33
- IP 33
- IP 33
- IP 33
- IP 33
- IP 33
- IP 33
- IP 33
- Accuracy:
- ±0,1% (0,1 rpm at 600 rpm)
- ±0,25% (1 rpm at 600 and 300 rpm; 0,1 rpm at 100 rpm)
- ±0,1% (0,01 rpm at 100 rpm)
- ±0,1% (0,01 rpm at 100 rpm)
- ±0,1% (0,1 rpm at 600 rpm)
- ±0,1% (0,1 rpm at 600 rpm)
- ±0,25% (1 rpm at 600 and 300 rpm; 0,1 rpm at 100 rpm)
- ±0,1% (0,01 rpm at 100 rpm)
- ±0,1% (0,01 rpm at 100 rpm)
- Anti-drip:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Cloud connected:
- No
- No
- No
- No
- No
- No
- No
- No
- No
- Digital dispensing:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Drive:
- 07522-20 (L/S® Standard Digital Drive, 600 rpm)
- 07522-20 (L/S® Standard Digital Drive, 600 rpm)
- 07522-30 (L/S® Standard Digital Drive, 100 rpm)
- 07522-30 (L/S® Standard Digital Drive, 100 rpm)
- 07522-20 (L/S® Standard Digital Drive, 600 rpm)
- 07522-20 (L/S® Standard Digital Drive, 600 rpm)
- 07522-20 (L/S® Standard Digital Drive, 600 rpm)
- 07522-30 (L/S® Standard Digital Drive, 100 rpm)
- 07522-30 (L/S® Standard Digital Drive, 100 rpm)
- Duty cycle:
- Continuous
- Continuous
- Continuous
- Continuous
- Continuous
- Continuous
- Continuous
- Continuous
- Continuous
- Min. RPM:
- 0,1 rpm
- 0,1 rpm
- 0,02 rpm
- 0,02 rpm
- 0,1 rpm
- 0,1 rpm
- 0,1 rpm
- 0,02 rpm
- 0,02 rpm
- Open-head sensor:
- No
- No
- No
- No
- No
- No
- No
- No
- No
- Pump series:
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- Remote I/O:
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- 4 to 20 mA, 0 to 10 V, start/stop and direction via contact closure
- Reversible motor:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Tubing:
- 96116-16, 8/pk (Bio-Pharm Plus Silicone, L/S® 16)
- 06434-16, 10-ft (C-FLEX® Ultra, L/S® 16)
- 06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)
- 06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)
- 96116-16, 8/pk (Bio-Pharm Plus Silicone, L/S® 16)
- 06434-24, 10-ft (C-FLEX® Ultra, L/S® 24)
- 06434-16, 10-ft (C-FLEX® Ultra, L/S® 16)
- 06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)
- 06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)
- Tubing sizes accepted:
- L/S® 13, 14, 16
- L/S® 13, 14, 16, 25, 17, 18
- Microbore Two-Stop Tubing Sets
- Microbore Two-Stop Tubing Sets
- L/S® 13, 14, 16
- L/S® 15, 24, 35, 36
- L/S® 13, 14, 16, 25, 17, 18
- Microbore Two-Stop Tubing Sets
- Microbore Two-Stop Tubing Sets
- Washdown capable:
- No
- No
- No
- No
- No
- No
- No
- No
- No
- Current:
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- 2,2 A @ 115 V; 1,1 A @ 230 V
- Frequency:
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- 50/60 Hz
- Voltage:
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- 90 - 260 VAC
- Warranty:
- 2 years
- 2 years
- 2 years
- 2 years
- 2 years
- 2 years
- 2 years
- 2 years
- 2 years
Product Information
- Electrical plug typeMaximum Flow RateIncluded accessoriesHousing materialPump headHeight
- L/S Eight-Channel, Four-Roller Cartridge Pump System; 115/230 VACL/S Eight-Channel, Four-Roller Cartridge Pump System; 115/230 VACEU144 ml/minEight small cartridges (07519-80)ABS plastic and aluminium07519-06 (L/S® Multichannel Cartridge Pump)215,9 mm1 * 1 items£5,680.00: MFLA77919-25-EU2 year warranty
Accessories
Specifications
Model77919-25No. of channels8Environmentally PreferableNo. of rollers4Control typeVariable-Speed DigitalMin. flow rate per channel0,0034 ml/minMax. flow rate per channel18 ml/minMin. flow rate0,0272 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,01 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-30 (L/S® Standard Digital Drive, 100 rpm)Duty cycleContinuousMin. RPM0,02 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)Tubing sizes acceptedMicrobore Two-Stop Tubing SetsWashdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 years2 year warranty - L/S Eight-Channel, Four-Roller Cartridge Pump System; 115/230 VACL/S Eight-Channel, Four-Roller Cartridge Pump System; 115/230 VAC5000144 ml/minEight small cartridges (07519-80)ABS plastic and aluminium07519-06 (L/S® Multichannel Cartridge Pump)215,9 mm1 * 1 items£5,680.00: MFLA77919-25-UK2 year warranty
Accessories
Specifications
Model77919-25No. of channels8Environmentally PreferableNo. of rollers4Control typeVariable-Speed DigitalMin. flow rate per channel0,0034 ml/minMax. flow rate per channel18 ml/minMin. flow rate0,0272 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,01 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-30 (L/S® Standard Digital Drive, 100 rpm)Duty cycleContinuousMin. RPM0,02 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)Tubing sizes acceptedMicrobore Two-Stop Tubing SetsWashdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 years2 year warranty - L/S Four-Channel, Eight Roller Cartridge Pump System; 115/230 VACL/S Four-Channel, Eight Roller Cartridge Pump System; 115/230 VACEU48 ml/minFour small cartridges (07519-85)ABS plastic and aluminium07519-20 (L/S® Multichannel Cartridge Pump)215,9 mm1 * 1 items£4,840.00: MFLA77919-35-EU2 year warranty
Accessories
Specifications
Model77919-35No. of channels4Environmentally PreferableNo. of rollers8Control typeVariable-Speed DigitalMin. flow rate per channel0,0024 ml/minMax. flow rate per channel12 ml/minMin. flow rate0,0096 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,01 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-30 (L/S® Standard Digital Drive, 100 rpm)Duty cycleContinuousMin. RPM0,02 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)Tubing sizes acceptedMicrobore Two-Stop Tubing SetsWashdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 years2 year warranty - L/S Four-Channel, Eight Roller Cartridge Pump System; 115/230 VACL/S Four-Channel, Eight Roller Cartridge Pump System; 115/230 VAC500048 ml/minFour small cartridges (07519-85)ABS plastic and aluminium07519-20 (L/S® Multichannel Cartridge Pump)215,9 mm1 * 1 items£4,840.00: MFLA77919-35-UK2 year warranty
Accessories
Specifications
Model77919-35No. of channels4Environmentally PreferableNo. of rollers8Control typeVariable-Speed DigitalMin. flow rate per channel0,0024 ml/minMax. flow rate per channel12 ml/minMin. flow rate0,0096 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,01 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-30 (L/S® Standard Digital Drive, 100 rpm)Duty cycleContinuousMin. RPM0,02 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06447-34, 12/pk (Tygon® E-LFL Two-Stop Tubing Set, 1,42mm ID)Tubing sizes acceptedMicrobore Two-Stop Tubing SetsWashdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 years2 year warranty - L/S Digital Pump System with Easy-Load 3 Pump Head, 600 RPM, 115/230VL/S Digital Pump System with Easy-Load 3 Pump Head, 600 RPM, 115/230VEU480 ml/minABS plastic and aluminium77800-60 (L/S® Easy-Load 3 Pump Head)215,9 mm1 * 1 items£3,860.00: MFLA77921-65-EUCE Compliant2 year warranty
Accessories
Specifications
Model77921-65No. of channels1Environmentally PreferableNo. of rollers3Control typeVariable-Speed DigitalMin. flow rate per channel0,08 ml/minMax. flow rate per channel480 ml/minMin. flow rate0,08 ml/minDrive IP ratingIP 33Accuracy±0,25% (1 rpm at 600 and 300 rpm; 0,1 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-20 (L/S® Standard Digital Drive, 600 rpm)Duty cycleContinuousMin. RPM0,1 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06434-16, 10-ft (C-FLEX® Ultra, L/S® 16)Tubing sizes acceptedL/S® 13, 14, 16, 25, 17, 18Washdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 yearsCE Compliant2 year warranty - L/S Digital Pump System with Easy-Load 3 Pump Head, 600 RPM, 115/230VL/S Digital Pump System with Easy-Load 3 Pump Head, 600 RPM, 115/230V5000480 ml/minABS plastic and aluminium77800-60 (L/S® Easy-Load 3 Pump Head)215,9 mm1 * 1 items£3,860.00: MFLA77921-65-UKCE Compliant2 year warranty
Accessories
Specifications
Model77921-65No. of channels1Environmentally PreferableNo. of rollers3Control typeVariable-Speed DigitalMin. flow rate per channel0,08 ml/minMax. flow rate per channel480 ml/minMin. flow rate0,08 ml/minDrive IP ratingIP 33Accuracy±0,25% (1 rpm at 600 and 300 rpm; 0,1 rpm at 100 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-20 (L/S® Standard Digital Drive, 600 rpm)Duty cycleContinuousMin. RPM0,1 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06434-16, 10-ft (C-FLEX® Ultra, L/S® 16)Tubing sizes acceptedL/S® 13, 14, 16, 25, 17, 18Washdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 yearsCE Compliant2 year warranty - L/S Digital Pump System with Easy-Load II Pump Head, 600 RPM, 115/230VL/S Digital Pump System with Easy-Load II Pump Head, 600 RPM, 115/230VEU1700 ml/minABS plastic and aluminium77200-62 (L/S® Easy-Load II Pump Head)215,9 mm1 * 1 items£3,540.00: MFLA77921-75-EUCE Compliant2 year warranty
Accessories
Specifications
Model77921-75No. of channels1Environmentally PreferableNo. of rollers4Control typeVariable-Speed DigitalMin. flow rate per channel0,28 ml/minMax. flow rate per channel1700 ml/minMin. flow rate0,28 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,1 rpm at 600 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-20 (L/S® Standard Digital Drive, 600 rpm)Duty cycleContinuousMin. RPM0,1 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing06434-24, 10-ft (C-FLEX® Ultra, L/S® 24)Tubing sizes acceptedL/S® 15, 24, 35, 36Washdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 yearsCE Compliant2 year warranty - L/S 4-Channel Digital Pump System w/Multichannel Head; 0,1-600 rpmL/S 4-Channel Digital Pump System w/Multichannel Head; 0,1-600 rpmEU1120 ml/minABS plastic and aluminium07535-04 (L/S® 4-Channel Pump Head)215,9 mm1 * 1 items£4,960.00: MFLA77921-85-EUISO9001
Accessories
Specifications
Model77921-85No. of channels4Environmentally PreferableNo. of rollers6Control typeVariable-Speed DigitalMin. flow rate per channel0,047 ml/minMax. flow rate per channel280 ml/minMin. flow rate0,188 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,1 rpm at 600 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-20 (L/S® Standard Digital Drive, 600 rpm)Duty cycleContinuousMin. RPM0,1 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing96116-16, 8/pk (Bio-Pharm Plus Silicone, L/S® 16)Tubing sizes acceptedL/S® 13, 14, 16Washdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 yearsISO9001 - L/S 4-Channel Digital Pump System w/Multichannel Head; 0,1-600 rpmL/S 4-Channel Digital Pump System w/Multichannel Head; 0,1-600 rpm50001120 ml/minABS plastic and aluminium07535-04 (L/S® 4-Channel Pump Head)215,9 mm1 * 1 items£4,960.00: MFLA77921-85-UKISO9001
Accessories
Specifications
Model77921-85No. of channels4Environmentally PreferableNo. of rollers6Control typeVariable-Speed DigitalMin. flow rate per channel0,047 ml/minMax. flow rate per channel280 ml/minMin. flow rate0,188 ml/minDrive IP ratingIP 33Accuracy±0,1% (0,1 rpm at 600 rpm)Anti-dripYesCloud connectedNoDigital dispensingYesDrive07522-20 (L/S® Standard Digital Drive, 600 rpm)Duty cycleContinuousMin. RPM0,1 rpmOpen-head sensorNoPump seriesL/SRemote I/O4 to 20 mA, 0 to 10 V, start/stop and direction via contact closureReversible motorYesTubing96116-16, 8/pk (Bio-Pharm Plus Silicone, L/S® 16)Tubing sizes acceptedL/S® 13, 14, 16Washdown capableNoCurrent2,2 A @ 115 V; 1,1 A @ 230 VFrequency50/60 HzVoltage90 - 260 VACWarranty2 yearsISO9001