Masterflex® L/S® High-Performance Precision Pump Tubing, Tygon® Fuel and Lubricant, Avantor®
Ideal for transferring hydrocarbons, gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants.
- Genuine Masterflex® tubing undergoes robust testing to provide optimal performance / pump life hours with peristaltic pump equipment
- Precision extruded to tight tolerances for high repeatability, accuracy and reproducibility
- Global market leader in range of formulations for most extensive chemical compatibility
- Single-use custom lengths and configurations available to minimise downtime
- Regulatory approvals to match your unique application
- Unique packaging options include packs, cases, and spools for customer-friendly ordering and delivery
Applications: Fuels and industrial lubricants—gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants
Characteristics: Resists most hydrocarbons, embrittlement, and swelling; ozone- and UV-resistant, low extractability, thermoplastic, PVC-based material with plasticizer, firm (stiff) material, translucent yellow
For custom tubing lengths and configurations, please contact us. We can provide the tubing type, length, and quantity you need.
- Environmentally Preferable:
- Model:
- 06401-36
- 06401-15
- 06401-35
- 06401-24
- Length per pack:
- 15,2 m (50 ft.)
- 15,2 m (50 ft.)
- 15,2 m (50 ft.)
- 15,2 m (50 ft.)
- Max. pressure:
- 1,4 bar (20 psi)
- 2,7 bar (40 psi)
- 2,4 bar (35 psi)
- 2,7 bar (40 psi)
- Min. temperature:
- –37 °C (–35 °F)
- –37 °C (–35 °F)
- –37 °C (–35 °F)
- –37 °C (–35 °F)
- Max. temperature:
- 74 °C (165 °F)
- 74 °C (165 °F)
- 74 °C (165 °F)
- 74 °C (165 °F)
- Min. temperature (dynamic):
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- Max. temperature (dynamic):
- 40 °C (104 °F)
- 40 °C (104 °F)
- 40 °C (104 °F)
- 40 °C (104 °F)
- Max. vacuum:
- 610 mm Hg (24" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- Pump series:
- L/S
- L/S
- L/S
- L/S
- Regulatory approvals:
- ADCF;Non-DEHP;Non-Phthalate;RoHS
- ADCF;Non-DEHP;Non-Phthalate;RoHS
- ADCF;Non-DEHP;Non-Phthalate;RoHS
- ADCF;Non-DEHP;Non-Phthalate;RoHS
- Sterilisation:
- Sterilization is not recommended
- Sterilization is not recommended
- Sterilization is not recommended
- Sterilization is not recommended
- Sterilisation method autoclave:
- No
- No
- No
- No
- Sterilisation method EtO:
- No
- No
- No
- No
- Sterilisation method gamma:
- No
- No
- No
- No
- Suction lift H₂O:
- 8,3 m (27 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- Warranty:
- 1 year
- 1 year
- Tubing int.ØTubing materialL/S Masterflex tubing sizeHose barb sizeMaximum Flow RatePk
- Tygon Fuel & Lubricant tubing (F-4040-A), L/S 15, 50 ft.Tygon Fuel & Lubricant tubing (F-4040-A), L/S 15, 50 ft.4,80 mm (0,189")Tygon® Fuel and Lubricant150,1875"1100 ml/min50 Feet1 * 50 Feet£192.00CE certificate
Specifications
Model06401-15Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure2,7 bar (40 psi)Min. temperature–37 °C (–35 °F)Max. temperature74 °C (165 °F)Min. temperature (dynamic)0 °C (32 °F)Max. temperature (dynamic)40 °C (104 °F)Max. vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsADCF;Non-DEHP;Non-Phthalate;RoHSSterilisationSterilization is not recommendedSterilisation method autoclaveNoSterilisation method EtONoSterilisation method gammaNoSuction lift H₂O8,8 m (29 ft.)Warranty1 year - Tygon Fuel & Lubricant tubing (F-4040-A), L/S 24, 50 ft.Tygon Fuel & Lubricant tubing (F-4040-A), L/S 24, 50 ft.6,40 mm (0,252")Tygon® Fuel and Lubricant240,25"1800 ml/min50 Feet1 * 50 Feet£245.00CE certificate
Specifications
Model06401-24Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure2,7 bar (40 psi)Min. temperature–37 °C (–35 °F)Max. temperature74 °C (165 °F)Min. temperature (dynamic)0 °C (32 °F)Max. temperature (dynamic)40 °C (104 °F)Max. vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsADCF;Non-DEHP;Non-Phthalate;RoHSSterilisationSterilization is not recommendedSterilisation method autoclaveNoSterilisation method EtONoSterilisation method gammaNoSuction lift H₂O8,8 m (29 ft.)Warranty1 year - Tygon Fuel & Lubricant tubing (F-4040-A), L/S 35, 50 ft.Tygon Fuel & Lubricant tubing (F-4040-A), L/S 35, 50 ft.7,90 mm (0,311")Tygon® Fuel and Lubricant350,375"2600 ml/min50 Feet1 * 50 Feet£301.00CE certificate
Specifications
Model06401-35Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure2,4 bar (35 psi)Min. temperature–37 °C (–35 °F)Max. temperature74 °C (165 °F)Min. temperature (dynamic)0 °C (32 °F)Max. temperature (dynamic)40 °C (104 °F)Max. vacuum660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsADCF;Non-DEHP;Non-Phthalate;RoHSSterilisationSterilization is not recommendedSterilisation method autoclaveNoSterilisation method EtONoSterilisation method gammaNoSuction lift H₂O8,8 m (29 ft.)Warranty - Tygon Fuel & Lubricant tubing (F-4040-A), L/S 36, 50 ft.Tygon Fuel & Lubricant tubing (F-4040-A), L/S 36, 50 ft.9,70 mm (0,382")Tygon® Fuel and Lubricant360,375"3400 ml/min50 Feet1 * 50 Feet£328.00CE certificate
Specifications
Model06401-36Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure1,4 bar (20 psi)Min. temperature–37 °C (–35 °F)Max. temperature74 °C (165 °F)Min. temperature (dynamic)0 °C (32 °F)Max. temperature (dynamic)40 °C (104 °F)Max. vacuum610 mm Hg (24" Hg)Pump seriesL/SRegulatory approvalsADCF;Non-DEHP;Non-Phthalate;RoHSSterilisationSterilization is not recommendedSterilisation method autoclaveNoSterilisation method EtONoSterilisation method gammaNoSuction lift H₂O8,3 m (27 ft.)Warranty