Masterflex® I/P® Precision Pump Tubing, Versilon™ A-60-N, Avantor®
Outlast and outperform other tubing with 10,000 hours of tubing life.
- Genuine Masterflex® tubing undergoes robust testing to provide optimal performance/pump life hours with peristaltic pump equipment
- Precision extruded to tight tolerances for high repeatability, accuracy, and reproducibility
- Global market leader in range of formulations for most extensive chemical compatibility
- Single-use custom lengths and configurations available to minimise downtime
- Regulatory Approvals to match your unique application
Masterflex® Norprene® Precision pump tubing is specially formulated not to weaken or crack after years of exposure to heat and ozone, providing longer peristaltic pump life. This tubing is heat sealable and weldable and able to withstand a broad range of temperature applications. Able to outperform other general-purpose tubing, Norprene features superior abrasion and flexural fatigue resistance, making it a better alternative to rubber tubing.
For custom tubing lengths and configurations, please contact us. We can provide the tubing type, length, and quantity you need.
- Environmentally Preferable:
- Catalog No:
- MFLX06404-26
- MFLX06404-82
- MFLX06404-73
- Model:
- 06404-26
- 06404-82
- 06404-73
- Length per pack:
- 15,2 m (50 ft.)
- 15,2 m (50 ft.)
- 15,2 m (50 ft.)
- Max. pressure:
- 2,7 bar (40 psi)
- 1,4 bar (20 psi)
- 2,7 bar (40 psi)
- Min. temperature:
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- Max. temperature:
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- Min. temperature (dynamic):
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- Max. temperature (dynamic):
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- Max. vacuum:
- 660 mm Hg (26" Hg)
- 510 mm Hg (20" Hg)
- 660 mm Hg (26" Hg)
- Pump series:
- I/P
- I/P
- I/P
- Regulatory approvals:
- Non-DEHP;Non-Phthalate;NSF-51;RoHS
- Non-DEHP;Non-Phthalate;NSF-51;RoHS
- Non-DEHP;Non-Phthalate;NSF-51;RoHS
- Sterilisation:
- Autoclave, Ethylene Oxide, Gamma Irradiation
- Autoclave, Ethylene Oxide, Gamma Irradiation
- Autoclave, Ethylene Oxide, Gamma Irradiation
- Sterilisation method autoclave:
- Yes
- Yes
- Yes
- Sterilisation method EtO:
- Yes
- Yes
- Yes
- Sterilisation method gamma:
- Yes
- Yes
- Yes
- Suction lift H₂O:
- 8,8 m (29 ft.)
- 7 m (23 ft.)
- 8,8 m (29 ft.)
- Warranty:
- Out of box
- 1 year
- SeqTubing int.ØTubing materialI/P Masterflex tubing sizeHose barb sizeMaximum Flow RatePk
- Tygon tubing A-60-G, I/P 26, 50 ft.Tygon tubing A-60-G, I/P 26, 50 ft.016,40 mm (0,252")Versilon™ A-60-N260,25"4000 ml/min50 Feet1 * 50 Feet£240.00CE certificate
Accessories
Specifications
Model06404-26Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure2,7 bar (40 psi)Min. temperature–51 °C (–60 °F)Max. temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. vacuum660 mm Hg (26" Hg)Pump seriesI/PRegulatory approvalsNon-DEHP;Non-Phthalate;NSF-51;RoHSSterilisationAutoclave, Ethylene Oxide, Gamma IrradiationSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)Warranty - Tygon tubing A-60-G, I/P 73, 50 ft.Tygon tubing A-60-G, I/P 73, 50 ft.029,50 mm (0,374")Versilon™ A-60-N730,375"8000 ml/min50 Feet1 * 50 Feet£287.00CE certificate
Accessories
Specifications
Model06404-73Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure2,7 bar (40 psi)Min. temperature–51 °C (–60 °F)Max. temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. vacuum660 mm Hg (26" Hg)Pump seriesI/PRegulatory approvalsNon-DEHP;Non-Phthalate;NSF-51;RoHSSterilisationAutoclave, Ethylene Oxide, Gamma IrradiationSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)Warranty1 year - Tygon tubing A-60-G, I/P 82, 50 ft.Tygon tubing A-60-G, I/P 82, 50 ft.0312,70 mm (0,500")Versilon™ A-60-N820,5"13000 ml/min50 Feet1 * 50 Feet£378.00CE certificate
Accessories
Specifications
Model06404-82Environmentally PreferableLength per pack15,2 m (50 ft.)Max. pressure1,4 bar (20 psi)Min. temperature–51 °C (–60 °F)Max. temperature132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Max. vacuum510 mm Hg (20" Hg)Pump seriesI/PRegulatory approvalsNon-DEHP;Non-Phthalate;NSF-51;RoHSSterilisationAutoclave, Ethylene Oxide, Gamma IrradiationSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O7 m (23 ft.)WarrantyOut of box