Microplate reader, Gemini™ EM
Supplier: MOLECULAR DEVICES
Certificates
About this item
Specifications
- Catalog No:
- MLDVEM
- MLDVEM-SC-ACAD
- Model:
- Gemini™ EM
- Gemini™ EM
- Light source:
- Xenon flash lamp (1 joule/flash)
- Xenon flash lamp (1 joule/flash)
- Detector:
- Photomultiplier (R-3896)
- Photomultiplier (R-3896)
- Wavelength range:
- 250 - 850 nm (excitation), 360 - 850 nm (emission)
- 250 - 850 nm (excitation), 360 - 850 nm (emission)
- Wavelength selection:
- 1,0 nm increments
- 1,0 nm increments
- Wavelength accuracy:
- ±2,0 nm
- ±2,0 nm
- Wavelength bandwidth:
- 9 nm
- 9 nm
- Incubation range:
- Ambient +4 °C to 45 °C
- Ambient +4 °C to 45 °C
- Measurement time:
- Reads a 96-well plate in <15 s, 384-well plate in <45 s
- Reads a 96-well plate in <15 s, 384-well plate in <45 s
- Software:
- SoftMax® Pro
- SoftMax® Pro
- Temperature uniformity:
- <1 °C at 37 °C set point
- <1 °C at 37 °C set point
- W×D×H:
- 580×380×220 mm
- 580×380×220 mm
- Weight:
- 16 kg
- 16 kg
Specifications
Related Information
Product Information
- Catalog #Supplier #PkAvailabilityPrice
- Gemini™ EM microplate reader, multi-mode,with current version of SoftMax® ProGemini™ EM microplate reader, multi-mode,with current version of SoftMax® ProMLDVEMEM11 * 1 items£0.00
Accessories
Specifications
ModelGemini™ EMLight sourceXenon flash lamp (1 joule/flash)Environmentally PreferableDetectorPhotomultiplier (R-3896)Wavelength range250 - 850 nm (excitation), 360 - 850 nm (emission)Wavelength selection1,0 nm incrementsWavelength accuracy±2,0 nmWavelength bandwidth9 nmIncubation rangeAmbient +4 °C to 45 °CMeasurement timeReads a 96-well plate in <15 s, 384-well plate in <45 sSoftwareSoftMax® ProTemperature uniformity<1 °C at 37 °C set pointW×D×H580×380×220 mmWeight16 kg - Gemini™ EM microplate reader, multi-mode, with current version of SoftMax® Pro and 1 additional year MRC service plan covering parts and labourGemini™ EM microplate reader, multi-mode, with current version of SoftMax® Pro and 1 additional year MRC service plan covering parts and labourMLDVEM-SC-ACADEM-SC-ACAD11 * 1 items£0.00
Accessories
Specifications
ModelGemini™ EMLight sourceXenon flash lamp (1 joule/flash)Environmentally PreferableDetectorPhotomultiplier (R-3896)Wavelength range250 - 850 nm (excitation), 360 - 850 nm (emission)Wavelength selection1,0 nm incrementsWavelength accuracy±2,0 nmWavelength bandwidth9 nmIncubation rangeAmbient +4 °C to 45 °CMeasurement timeReads a 96-well plate in <15 s, 384-well plate in <45 sSoftwareSoftMax® ProTemperature uniformity<1 °C at 37 °C set pointW×D×H580×380×220 mmWeight16 kg