Gas detection tubes for sulphur dioxide
: Dräger
To measure the 'spot concentrations' of sulphur dioxide for use with an Accuro® pump.
Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.
The tube sulphur dioxide1/a has a prelayer so that H₂S in the TLV range is retained and does not interfere. Hydrogen sulphide and acidic gases may interfere with other tubes.
One stroke is equivalent to a volume of 100 ±5 ml of gas passing through the tube.
The standard measuring range is calibrated at 20 °C and 1013 hPa.
- Catalog No:
- 118-0308
- 151-0146
- 151-0207
- 151-0194
- 151-0154
- Model:
- Sulphur dioxide 50/b
- Sulphur dioxide 0.1/a
- Sulphur dioxide 1/a
- Sulphur dioxide 20/a
- Sulphur dioxide 0.5/a
- Colour change:
- Blue to yellow
- Yellow to orange
- Grey blue to white
- Brown yellow to white
- Grey blue to white
- Humidity:
- 1 -15 mg/l H₂O
- 3 -15 mg/l H₂O
- 3 -20 mg/l H₂O
- ≤ 30 mg/l H₂O
- ≤ 20 mg/l H₂O
- Measurement time:
- 15 seconds/3 minutes
- 20 minutes
- 3 minutes
- 3 minutes
- 3/6 minutes
- No. of strokes:
- 1/10
- 100
- 10
- 10
- 10/20
- Standard deviation:
- ±10 - 15 %
- ±10 - 15 %
- ±10 - 15 %
- ±10 - 15 %
- ±10 - 15 %
- Standard range:
- 400 - 8000 / 50 - 500 ppm
- 0,1 - 3 ppm
- 1 - 25 ppm
- 20 - 200 ppm
- 1 - 25/0,5 - 5 ppm
- Temperature range:
- 0…50 °C
- 10…30 °C
- 15…25 °C
- 0…40 °C
- 15…30 °C
Product Information
- Catalog #Supplier #RangePkAvailabilityPrice
- Sulphur dioxide 0,1/aSulphur dioxide 0,1/a151-014667271010,1 - 3 ppm101 * 10 items£114.00: 6727101: DRAE6727101
Specifications
ModelSulphur dioxide 0.1/aEnvironmentally PreferableColour changeYellow to orangeHumidity3 -15 mg/l H₂OMeasurement time20 minutesNo. of strokes100Standard deviation±10 - 15 %Standard range0,1 - 3 ppmTemperature range10…30 °C - Sulphur dioxide 0,5/aSulphur dioxide 0,5/a67284910,5 - 25 ppm101 * 10 items£145.00: 6728491: DRAE6728491
Specifications
ModelSulphur dioxide 0.5/aEnvironmentally PreferableColour changeGrey blue to whiteHumidity≤ 20 mg/l H₂OMeasurement time3/6 minutesNo. of strokes10/20Standard deviation±10 - 15 %Standard range1 - 25/0,5 - 5 ppmTemperature range15…30 °C - Sulphur dioxide 1/aSulphur dioxide 1/aCH317011 - 25 ppm101 * 10 items£102.00: CH31701: DRAECH31701
Specifications
ModelSulphur dioxide 1/aEnvironmentally PreferableColour changeGrey blue to whiteHumidity3 -20 mg/l H₂OMeasurement time3 minutesNo. of strokes10Standard deviation±10 - 15 %Standard range1 - 25 ppmTemperature range15…25 °C - Sulphur dioxide 20/aSulphur dioxide 20/a151-0194CH2420120 - 2000 ppm101 * 10 items£112.00: CH24201: DRAECH24201
Specifications
ModelSulphur dioxide 20/aEnvironmentally PreferableColour changeBrown yellow to whiteHumidity≤ 30 mg/l H₂OMeasurement time3 minutesNo. of strokes10Standard deviation±10 - 15 %Standard range20 - 200 ppmTemperature range0…40 °C - Sulphur dioxide 50/bSulphur dioxide 50/b118-0308810153150 - 8000 ppm101 * 10 items£114.00: 8101531: DRAE8101531
Specifications
ModelSulphur dioxide 50/bEnvironmentally PreferableColour changeBlue to yellowHumidity1 -15 mg/l H₂OMeasurement time15 seconds/3 minutesNo. of strokes1/10Standard deviation±10 - 15 %Standard range400 - 8000 / 50 - 500 ppmTemperature range0…50 °C