VWR® Electrode Holders
Supplier: VWR Chemicals
Plain borosilicate tubes for insertion of a wire electrode so that the electrode is insulated from the clamp or holder and protected from mechanical damage. The tube also helps the flexible wire electrode be positioned correctly in a rigid support.
Expand 1 Items
Digital storage oscilloscopes
Supplier: DIDALAB
A range of digital storage oscilloscopes with bandwidth from 150 to 500 MHz.
Expand 4 Items
Analogue oscilloscopes
Supplier: 3B Scientific
Educational Materials, Electricity/Magnetism, Application: Physics, Analogue oscilloscope, 30 MHz, microprocessor controlled
Expand 1 Items
Adapter, BNC connector to 4 mm jack plugs
Supplier: 3B Scientific
Educational Materials, Electricity/Magnetism, Application: Physics, Adapter, BNC connector to 4 mm Jack plugs with 19 mm spacing.
Expand 1 Items
Tube holder S
Supplier: 3B Scientific
Tube holder to support all S series electron tubes for easy and safe operation. The five pin sockets for the tube are concealed inside the tube holder. A cathode protection switch is integrated into the tube holder, to protect the heated cathode from excessive voltage. The base plate has a slot for attaching the Helmholtz pair of coils S.
Expand 1 Items
Maltese cross tube
Supplier: 3B Scientific
Evacuated glass flask containing i.a. electron gun with directly heated tungsten wire cathode and a cylindrical anode. The electron gun emits a divergent electron beam, aimed at an Maltese cross of aluminum placed in the middle of the tube. The cross can be connected electrically. At the same time, light from the filament is also directed towards the cross, so that a comparison can be made between the shadows of different types that appear on the luminescent surface at the far end of the tube. Specifications.
Expand 1 Items
Electron deflection tube D
Supplier: 3B Scientific
Highly evacuated electron tube with focusing electron gun and fluorescent screen (90×60 mm) inclined relative to the beam axis, so that the path of the beam can be seen and the effects of electric and magnetic fields can be studied. The electron beam can be deflected electrically in the electric field of the built-in plate capacitor, and magnetically by using an optional Helmholtz coil pair D. By adjusting the electric field so that it cancels the magnetic deflection, it is possible to determine the specific charge e/m and the velocity of the electrons.
Expand 1 Items
Electron diffraction tube D
Supplier: 3B Scientific
Highly evacuated electron tube for determining the wavelength of electrons as a function of the anode voltage from the radii of the diffraction rings and the distance between the lattice planes of graphite (Debye-Scherrer-diffraction) and rendered visible on a fluorescent screen. Also intended for determining the wavelengths of monochromatic radiation at different anode voltages from the radii of the diffraction rings and the lattice plane spacing of graphite, as well as confirming de Broglie’s hypothesis.